en Installation instructions
room-air-dependent heat-producing appli-
ance is being operated.
It is only possible to safely operate the appli-
ance if the pressure in the room in which the
heating appliance is installed does not fall
below 4 Pa (0.04 mbar). This can be
achieved whenever the air needed for com-
bustion is able to enter through openings
that cannot be sealed, for example in doors,
windows, incoming/exhaust air wall boxes or
by other technical means. An incoming/ex-
haust air wall box alone is not sufficient to
ensure compliance with the limit.
In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will sug-
gest the suitable ventilation measures to
you.
Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulating-
air mode.
Risk of poisoning from flue gases being drawn
back in.
If an extractor hood with an open-flued heat
production source is installed, the power
supply for the extractor hood must be
provided with a suitable safety switch.
Risk of poisoning from flue gases being drawn
back in.
Do not emit the exhaust air into a smoke or
exhaust gas flue that is in operation.
Do not emit the exhaust air into a shaft that
is used to ventilate installation rooms for
heat-producing appliances.
If the exhaust air is to be conveyed into a
smoke or exhaust gas flue, you must obtain
the consent of the heating engineer respons-
ible.
WARNING ‒ Risk of suffocation!
Children may put packaging material over their
heads or wrap themselves up in it and suffoc-
ate.
Keep packaging material away from chil-
dren.
Do not let children play with packaging ma-
terial.
WARNING ‒ Risk of fire!
The grease deposits in the grease filter may
catch fire.
Never work with naked flames close to the
appliance (e.g. flambéing).
Do not install the appliance near a heat-pro-
ducing appliance for solid fuel (e.g. wood or
36
coal) unless a closed, non-removable cover
is present. There must be no flying sparks.
The specified safety clearances must be
complied with in order to prevent a build-up
of heat.
Observe the specifications for your cooking
appliances. If the installation instructions for
the cooking appliances specify a different
clearance, the larger of the two must always
be provided for. If gas hobs and electric
hobs are operated together, the largest spe-
cified clearance applies.
WARNING ‒ Risk of injury!
Components inside the appliance may have
sharp edges.
Wear protective gloves.
The appliance may fall down if it has not been
properly fastened in place.
All fastening components must be fixed
firmly and securely in place.
The appliance is heavy.
To move the appliance, two people are re-
quired.
Use only suitable tools and equipment.
The appliance is heavy.
The appliance must not be fitted directly
onto plasterboard or similar lightweight ma-
terials.
To ensure correct installation, you must use
a material which is sufficiently stable and
suitable for both the structural conditions
and the weight of the appliance.
Changes to the electrical or mechanical as-
sembly are dangerous and may lead to mal-
functions.
Do not make any changes to the electrical
or mechanical assembly.
Risk of falling when working on the appliance
Use a stable stepladder.
Do not lean over the hob.
Do not step on the hob or the work surface.
The filter cover may swing out.
Open the filter cover slowly.
Take hold of the filter cover after opening un-
til it no longer swings out.
Close the filter cover slowly.