Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Honda EM50IS Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für EM50IS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

When the engine will not start:
Is there fuel in
the tank?
YES
Is the engine
switch ON?
YES
Is the fuel vale
lever on?
YES
Is the enough oil
in the engine?
YES
Is the spark plug
in good
condition?
YES
Is the fuel
reaching the
carburetor?
YES
If the engine still
does not start,
take the
generator to an
authorized
Honda dealer.

10. TROUBLESHOOTING

NO
NO
NO
NO
NO
NO
To check:
1)Turn off the fuel valve
lever and loosen the
drain screw.
2)Turn on the fuel valve
lever. Fuel should flow
from the drain.
Refill the fuel
tank (see page
23).
Turn the engine
switch ON.
Turn the fuel
valve lever ON.
Add the
recommended
oil (see page 21).
Clean, readjust
gap and dry the
spark plug.
Replace it if
necessary (see
page 47).
Clean the fuel
sediment cup
(see page 46).
57

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Em65is

Inhaltsverzeichnis