7.FUSE REPLACEMENT

If the fuse is blown, the starter motor will not work until it is replaced.
In the event of fuse failure, locate the cause of failure and repair it
before you continue operation. If the fuse continues to fail, discontinue
generator use and consult an authorized Honda generator dealer.
1.Unscrew the four 6×10 mm flange bolts, and remove the side panel.
6×10 mm
FLANGE BOLT (4)
SIDE PANEL
2.Turn the engine switch to the OFF position and remove the key before
checking or replacing the fuse.
3.Remove the fuse holder cover and replace the fuse.
The specified fuse is 20A.
CAUTION:
• If frequent fuse failure occurs, determine the cause and correct the
problem before attempting to operate the generator further.
• Never use a fuse with a different rating from that specified. Serious
damage to the electrical system or fire may result.
4.Install the fuse holder cover in the reverse order of removal.
5.Reinstall the side panel using the four 6×10 mm flange bolts.
FUSE (20 A)
FUSE HOLDER COVER