Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

36Z376000.book 66 ページ 2014年9月19日 金曜日 午後6時26分
SERVICING YOUR GENERATOR

FUSE

If the fuse is blown, the starter motor will not operate.
In the event of fuse failure, locate the cause of failure and repair it
before you continue operation. If the fuse continues to fail, discontinue
generator use and consult your servicing dealer.
1.Turn the MAIN switch to the OFF position and remove the key before
checking or replacing the fuse.
2.Loosen the cover screw and
remove the battery
maintenance cover.
3.Remove the fuse holder cover
and pull the fuse out.
4.Replace the fuse with a 
fuse of the same type and
rating.
Specified fuse: 3 A, 15 A
Never use a fuse with a
different rating from that
specified. Serious damage to
the electrical system or fire
may result.
5.Install the fuse holder cover and the battery maintenance cover in
the reverse order of removal (see page 63).
Never operate the generator with the battery maintenance cover
open, as poor engine and generator performance will result.
66
BATTERY MAINTENANCE COVER
FUSE (15 A)
FUSE (3 A)
FUSE HOLDER COVER
COVER
SCREW

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis