36Z376000.book 89 ページ 2014年9月19日 金曜日 午後6時26分

HANGER KIT

Protect the fuel tank and frame pipe with the protector films during
installation of the hanger.
1.Slide one end of the hanger under the frame pipe on the left side of
the generator.
2.Slide the other end of the hanger under the frame pipe on the right
side of the generator.
3.Slide the hanger along the frame pipes to align the center of the
hanger with the recessed part on the rear side of the fuel tank.
4.Install the hanger brackets on both ends of the hanger and tighten
the 8×16 mm flange bolts securely.
TORQUE: 24–29 N·m (2.4–3.0 kgf·m, 17–22 lbf·ft)
OPTIONAL PARTS
HANGER
HANGER
PROTECTOR FILM
(commercially available)
8×16 mm FLANGE BOLT (4)
HANGER
BRACKET (2)