AC OPERATION

Connect a RCBO (Residual current circuit breaker with overload
protection) of 30 mA ground fault detection and cut-off of less than
0.4 seconds at more than 30 A of output current, if you are using two
or more appliance.
Follow the instructions provided by each RCBO manufacturer before
use.
GENERATOR
RCBO
Connecting with one RCBO
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance, and
determine whether the problem is in the appliance or the rated load
capacity of the generator has been exceeded.
Substantial overloading that continuously lights the red OVERLOAD
ALARM indicator may damage the generator. Marginal overloading that
temporarily lights the red OVERLOAD ALARM indicator may shorten
the service life of the generator.
1.Start the engine and make
sure the green OUTPUT
indicator comes on.
APPLIANCES
GENERATOR
OUTPUT INDICATOR (GREEN)
OPERATION
APPLIANCES
RCBO
RCBO
Connecting with two RCBO
39