8 Installation instructions

8.1 Installation

1. Drill a 20 mm (0,79 inch) diameter hole at
least 89 mm (3,5 inches) deep. The drilled
hole must be straight and perpendicular to
the surface. Make sure the hole is of uniform
diameter and free of defects on the inner
wall.
Drill
Drill
Ø Ø 20 mm
20 mm
Hole drilling requirement chart
(A) Min. Edge/
Corner distance
15.3 cm (6 in)
30.5 cm (12 in)
2. Blow hole clean with compressed air.
3. Always inspect the hole carefully when reus‑
ing a previously drilled hole.
4. When placing anchor, place your thumb on
the button and your first two fingers around
the stop sleeve.
5. Squeeze your fingers and thumb together
and compress the stop sleeve and button
together.
6. Blow hole clean with compressed air.
7. Always inspect the hole carefully when reus‑
ing a previously drilled hole.
(A) cm
(B)
cm
(B) Concrete
thickness
30.5 cm (12 in)
12.7 cm (5 in)
8. When placing anchor, place your thumb on
the button and your first two fingers around
the stop sleeve.
9. Squeeze your fingers and thumb together
and compress the stop sleeve and button
together.

8.2 Removal

1. When removing anchor, place your thumb on
the button and your fingers around the stop
sleeve.
2. Squeeze your fingers and thumb together
and compress the stop sleeve and button
together.
3. While compressing, pull the anchor out of
the hole.
4. If the anchor is stuck, lightly tap the button
with a hammer. Striking the anchor with force
is not necessary. A light tap is enough to dis‑
engage the inner shaft from the spoons.
5. If the hammer was required to remove the
anchorage connector, inspect the anchor‑
age connector thoroughly for damage after
removal. If damage is found remove from
service and destroy immediately.