they must be replaced. Replace and tighten the drain screw. After this operation, add
fresh oil to the upper level on the dipstick.
WARNING! Hot surfaces! Wear protective gloves!
Air filter
The air filter should be inspected for technical condition. It should be unscrewed and
cleaned or replaced with a new one. The filter should be washed with water and a
mild detergent, dried and replaced. Do not start the engine with the air filter
disassembled.
Fuel filter
The fuel filter should be inspected after every 150 hours of operation or after 3
months of use. Remove and clean the fuel filter. Unscrew the fuel tank cap, clean it in
water with a mild detergent, dry and replace it.
Battery maintenance
Batteries installed in the machines do not require refilling or special maintenance.
Make sure that the terminals are not covered with dust and rust. Corrosion can cause
improper battery operation and may be dangerous. If you notice any signs of
corrosion, disconnect terminals and remove the rust cleaning the terminals and
connectors with lye – a solution of baking soda and water (sodium bicarbonate).
Cover the terminals with antioxidant grease before
reconnecting and tightening them.
Storage
Before storing the machine, remember to do the following.
1. Disconnect the spark plug wire to prevent accidental start.
2. Clean the machine and dispose of the chips.
3. Leave the machine on a flat surface in a well-ventilated room out of reach of
direct sunlight.
4. Do not store the machine with ignition sources present, such as a stove, gas or
electric heater, etc.
5. Do not store the machine in places where exhaust or toxic gases can enter the
living quarters.
6. Put the covers on the loading hopper and outlet chute.
7. If the machine is not to be used for more than 30 days, drain the tank and the
carburetor. Unscrew the spark plug and pour approximately 5 ml of engine oil
through the cylinder plug hole. With the switch in the OFF position, gently pull
the starter cord several times. Screw back the spark plug and pull the starter cord
until you feel resistance, and do not pull any more.