3.7 ELECTRICAL CONNECTION
Electrical connection may only be performed by a qualified specialist. Covers marked
with this symbol may only be removed by a qualfied specialist.
•
The statutory regulations and connection conditions of the local electrical supply
company must be observed in full.
•
When the appliance is connected, a device must be provided which makes it possible
to disconnect the appliancefrom the mains with an opening width of at least 3 mm
all poles using a contact. LS switches, fuses and contactors are regarded as suitable
disconnecting devices. When connecting and repairing the device, disconnect from the
power suppyusing one of these devices.
•
The protective conductor must be long enough so that if the strain relief fails, it will only
be subjected to tensile stress after the current-carrying cores of the connecting cable.
•
The excess cable length must be pulled out of the installation area below the device.
•
Please make sure that the mains voltage is the same as on the nameplate.
•
Complete protection against accidental contact must be ensured by installation.
•
Attention: incorrect connection can lead to destruction of the power electronics.
•
The device is only approved for a fixed connection. It must not be connected with a
shock-proof plug.
Connecting cable available at the factory
•
The hob is equipped with a temperature-resistant connection cable at the factory.
•
The mains connection is carried out according to the connection diagram, except the
connection cable is already equipped with a plug.
•
If the power cable is damaged, it must be replaced with a special power cable. In order
to avoid hazards, this may only be done by the manufacturer or his customer service.
ONE PHASE CONNECTION 1N 220-
240 V 50/60 HZ 5X1.5 MM²
L1
N
BLACK
BROWN
BLUE
BLUE
GREEN/YELLOW
TWO PHASES CONNECTION 2N 380-
415 V 50/60 HZ 5X1.5 MM²
L1
L2
N
GREEN/YELLOW
BLACK
BROWN
BLUE
BLUE
PRIMA SLIM | 63