Marking / Test certificate nos.:
IU.4-......-.....
IF.4-......-.....
*: Manufacturer's declaration (Document SAG04ATEX002)
Temperature range / Output parameters:
IU.4-......-.....
IF.4-......-.....
*: The temperature range may be restricted for operational reasons (please see Data Sheet for platform) .
Instructions and information:
1)
Install the equipment in compliance with applicable laws, rules and regulations,
ordinances and standards. In particular, be sure to conform to the European Standards
EN 60079-14 (Electrical apparatus for use in potentially explosive atmospheres) and EN
50281-1-2 (Electrical apparatus for use in the presence of combustible dust).
2)
Be sure to follow the installation, operating, maintenance and servicing instructions given
in the manuals supplied.
3)
The cable glands must be secured so that they cannot work loose.
4)
The housing of equipment connected to power may only be opened outside the
hazardous area.
5)
All metallic parts (housing, column, load plate, drive-on ramp, bench, etc.) must be
electrically connected to the terminal for the equipotential bonding conductor so that any
electrostatic charges can be conducted away from the equipment.
6)
Avoid generating static electricity. Use only a damp cloth to wipe down the equipment.
7)
If you wish to use other manufacturer's equipment in a Zone 2 hazardous area, be sure
that it has the required group and temperature class; to use such equipment in Zone 22,
make sure that this equipment has the maximum surface temperature specified.
8)
If you plan to use the equipment in Zone 22: prevent a layer of dust of more than 5 mm
from accumulating on the equipment.
9)
Observe the installation instructions and information for equipment connected to the
platform, such as 35751-000-16-A4 for ISI or QCT connections and 35739-004-16-A4 for
connecting CIS. + Option Y2.
Date
11.06.04
Written by
11.06.04
Reviewed by
11.06.04
Released by
12
Pallet Scale/Flat-bed Scale: Option Y2
II 3 GD
EEx nA
II 3 GD
EEx nA
-20°C ... +40°C
-20°C ... +40°C
Name
Designation
Klausgrete
Weitemeier
Drawing No.
Klausgrete
II
T6 T80°C IP65/67 (*)
II
T6 T80°C IP65/67 (*)
(*)
---
(*)
---
Installation Instructions
36116-751-61-A4
Revision
3
3
Page
of
00