Silence
Mode
You can silence the device by pressing the test/silence button on the device or tapping the si ence button in
the app.
f you press the silence button during an alarm state, the device will say"Rauchmelder stummgeschaltet."
and a push notification wil be sent to your phone (when connected to the base station). Then the unit wil
be in the silence mode for 9 minutes. During the silence mode, the LEDflashes red 3 times every 4 seconds.
After 9 minutes, the LEDwill flash green 3 times and the alarm wil enter the normal mode.
When
Connected
to the
Base
Station
You can si ence the base station and al interlinked alarms when smoke is detected by pressing the Si ence
button on the base station or by tapping the Silence button in the app.
You can tap the Locate button in the app to find the initiating alarm; all devices will stop alarming except the
initiating alarm. Simp y silence the initiating a arm by tapping the silence icon in the app or by pressing the
test/silence
button
on the device.
When
Not
Connected
to the
Base
Simply press the test/si ence button on one of the devices to silence the interconnected system, however
only silencing the initiating alarm wi si ence al other interconnected alarms.
The initiating alarm will report the voice "Rauchmelder stummgeschaltet." and all other interconnected
alarms
won't.
NOTES
1.Youcan silenceall interconnectedunits by pressingthetest/silencebutton on one ofthe units.Ifone unit isstill
alarming, it is the initiating unit (the unit that detected danger); to silenceall interlinked units,you must alsopress
the test/silencebutton on theinitiating unit.
2. Whileinterconnected,theinitiating unit cannot be triggered again during the 9-minute silenceduration. However,
all other interconnectedunits can be triggered again if theydetect dangerduring the silencemode.
Station
.16.
Battery Replacement
Low Battery
The LED indicator flashes yel ow once every 60 seconds. For the first 15 minutes, the device wil give a verba
warning "Achtung! Schwache Batterie. Tauschen Sie die Batterie jetzt aus."every 60 seconds. After 15 minutes,
the device wi stop the voice alert and beep once every 60 seconds.
(If you press the test button when there is ow battery, the ow battery signal will temporarily cease for 10
hours.)
Replacing
Battery
1.To replace the battery, detach the smoke alarm from the mounting bracket by twisting counterclockwise.
2. Remove the battery, and then install a new battery, matching the correct polarity markings.
3.Test the alarm, and then mount the alarm onto the mounting bracket by twisting clockwise to ock the
alarm.
End of Life
When the device reaches its end of life, the LED indicator
first 15 minutes, the device will give a verbal warning "Vorsicht. Der Melder hat das Ende seiner Lebensdauer
erreicht. Tauschen Sie das Gerätjetzt aus: After 15 minutes, the device will stop the voice alert and beep 3
times every 60 seconds. This end of-life signal can be temporari y silenced for 22 hours by pressing the test
button.
The end-of-life silence feature can on y be used for a total of 30 days.After 30 days,the end-of-life signal
cannot
be silenced.
wil
flash yel ow 3 times every 60 seconds. For the