4. Scope of delivery
Difficult installation due to inaccurate holes
The fitting cannot be installed if the fastening holes and the spindle do not
match.
Make sure that the fastening holes and the spindle are in parallel ver-
tical lines.
NOTE
Effect on the mortise lock
The PegaSys DoorHandle 4.1 acts exclusively on the latch of the mortise
lock.
Locking and insurances
Insurance companies place increased demands on a closure.
1.
If you want to lock the door under insurance law, use a self-locking
panic lock or a locking cylinder in addition to the PegaSys DoorHandle
4.1.
2.
Pay attention to the approvals according to EN 179.
PegaSys DoorHandle 4.1 with self-locking panic lock
The PegaSys DoorHandle 4.1 only offers full functionality with a self-locking
panic lock.
1.
Combine the PegaSys DoorHandle 4.1 with a self-locking panic lock.
2.
Pay attention to the declarations of conformity of the lock manufactur-
ers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad excludes authorisation
security class D according to DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to manipulate the lock.
1.
Seal any escutcheon holes with a blind cylinder, for example.
2.
In the case of FH versions, you must be install a brass dummy cylinder or
locking cylinder.
4. Scope of delivery
PegaSys DoorHandle 4.1 (stationary installation)
Special tool
Quick guide
Depending on version:
Adapter set, 7 mm spindle
Adapter sleeve, 8.5 mm spindle
Adapter sleeve, 10 mm spindle
Blank cylinder
5. Design
1
6. Prepare door (drilling template)
Pin or scriber at hand.
ü
Drill at hand.
ü
Suitable drill bit at hand (depending on mortise lock hole diameter:
ü
8.5 mm/9.5 mm/10.5 mm).
PH2 screwdriver at hand.
ü
1.
Insert the spindle into the mortise lock.
2
2.
Place the drilling template on the spindle.
3
3.
Align the drill template vertically using the printed scale.
4.
Mark the points to be drilled on the door.
4
30 / 44
PegaSys Door Handle 4.1 Stationary installation
5.
Remove the drilling template.
5
6.
Remove the spindle.
6
7.
Remove the mortise lock (PH2).
7
8.
Measure the diameter of the fastening holes.
8
Ø fastening holes
5.5 mm–6.3 mm
6.4 mm–7.3 mm
7.4 mm–8.7 mm
≥ 8.8 mm
9.
Determine the required drill bit based on the measured diameter.
10. Drill the required holes.
9
11.
Fit the mortise lock (PH2).
10
7. For door thickness X: prepare threaded
rods and spindle
ü
Saw at hand.
ü
Vernier calliper at hand.
ü
PH2 screwdriver at hand.
1.
For X: measure the door thickness.
11
2.
For X: fasten the screws, threaded sleeves and threaded rods together.
12
3.
For X: mark the sawing points on the threaded rods and spindle.
13
14
15
4.
For X: use a suitable saw to cut the threaded rods and spindle.
16
8. Programming the fitting
17
9. Installing the fitting
ü
Door pre-drilled.
ü
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
Vernier calliper at hand.
ü
Pincers at hand.
ü
1.
For S, M and L: measure the door thickness.
18
2.
For S, M and L: determine the separation points on the cut-to-length
screws L1 and L2.
19
20
3.
For S, M and L: trim the cut-to-length screws L1 and L2.
21
Drill bits required
8.5 mm
8.5 mm
9.5 mm
10.5 mm
EN