DCM300MINI
Alternating current or voltage, direct current or
,
voltage
Diode test, continuity test
Automatic measuring range mode
Automatic power-off state
LOW BATTERY
Display hold
High voltage warning symbol
3. Specifications
Accuracy is given as ± (% of reading + counts of least
significant digit) at 23°C ± 5°C, with relative humidity less
than 80% R.H., and is specified for 1 year after calibration.
3.1 General
Automatic measuring range and manual measuring range.
Full measuring range overload protection.
The maximum allowable voltage between measurement
end and ground: 600V DC or AC(RMS) Operating altitude:
2000m (6562 ft.)
Display: LCD
Displayed maximum value: 4000 counts.
Polarity indication: automatically indication, "-" mean:
negative polarity.
Exceeding measuring range display: " OL"
Sampling rate: about 3 times/sec.
Unit display: has function and power unit display.
Auto power off time: 15 min
Power supply: 3x1.5V AAA Batteries
Battery under voltage indication: LCD displays
Temperature Coefficient: 0.2 x (Specified accuracy) / °C,
<18°C, > 28°C
Operating temperature:
0°C to 30°C (≤ 80% R.H.) 30°C to 40 °C (≤ 75% R.H.) 40°C
to 50 °C (≤ 45% R.H.)
Storage Temperature:
-20°C to 60 °C (≤ 80% R.H., no batteries)
6
EN
symbol.