Replacing the HEPA filter
It is recommended that the HEPA filter on
the UltraVent Plus condensation hood be
replaced annually.
a
The unit on which the condensation
hood is to be installed is disconnected
from the mains.
a
The condensation hood is disconnec-
ted from the mains.
1. Unlock the impact filter and remove
the impact filter on the left and right
[
Figure
37].
2. Remove the cover at the front left
[
Figure
14].
3. Loosen the 4 screws on the left and
right of the front side, which attach the
front hood [
front section upwards.
4. Remove the 4 screws holding the filter
holder [
Figure
5. Pull the filter holder out of the con-
densation hood [
the filter holder over and place it on
top of the condensation hood.
6. Remove the 3 screws holding the
HEPA filter [
7. Replace the 2 HEPA filters
[
Figure
43].
NOTICE
Install the HEPA filter correctly
Be sure to observe the sticker on the
HEPA filter. If the installation direction
is correct, the black arrow on the sticker
points against the flow direction and
the sealing surfaces are not visible. The
correct installation direction is
necessary for correct installation and
operation of the HEPA filter.
26 / 160
Figure
39]. Remove the
40].
Figure
41], turn
Figure
42].
80.51.570_iCombiPro-iCombiClassic_UV-P_IM_EU-west
8. Mount the HEPA filter, the filter cas-
sette, the electrical compartment cover
and the baffle filter in reverse order.
7
Service parts
NOTICE
Availability of service parts
The service parts are available from the
catalogue of service parts.