English
14. Insert the right and left impact filters.
To secure the impact filter, pull the
locking latch on the left of the impact
filter to the left [
15. Hang the side panels on the left and
right of the condensation hood
[
Figure
16]. Make sure that the
sheet edge hangs between the nut and
the screw [
Figure
16. Only required for Combi-Duo: Re-
move the sealing plug from the back of
the condensation hood [
and fat the black seal in the opening.
17. Secure the touch protection on the
rear side of the condensation hood
with the 4 screws [
Guide the cables down the gap
between the back of the condensation
hood and the touch protection.
5.2 Electrical connection
DANGER
High voltages when connecting to the
mains power
Danger to life due to high voltage.
Disconnect from the power supply.
n
Make sure the unit is disconnected
n
from the power.
DANGER
Electric shock from incorrect
connection
There is a danger to life if the wires are
incorrectly connected.
Connect the wires correctly according
to their colour coding.
22 / 160
Figure
15].
17].
Figure
18]
Figure
19].
80.51.570_iCombiPro-iCombiClassic_UV-P_IM_EU-west
5.2.1 Regulations for electrical connection
General information
The UltraVent Plus condensation hood
n
must be connected to an electrical
supply in line with the valid standards
(VDE).
Before you disconnect the unit from
n
the mains or reconnect it to the mains,
make sure that the unit is switched off
to prevent the UltraVent Plus con-
densation hood from running.
The condensation hood must be fused
n
with a maximum of 16 A by the cus-
tomer.
Notes on the connection cable
The condensation hood must be
n
equipped with a power cable approx-
imately 2 metres long.
A separate power plug must be in-
n
stalled.
If the connection cable needs to be re-
n
placed, use a H05 RN-F 3x1.5 mm
quality cable.
The mains power cable may only be
n
replaced by qualified personnel au-
thorised by the manufacturer.
5.2.2 Connecting the bus cable
a
The condensation hood is installed on
the unit.
1. Remove the left side panel of the unit
(Combi-Duo: upper unit).
2. Break out the suitable hole for the PG
screw connection above the media
outlets on the rear side of the unit
[
Figure
21].
3. Pass the bus cable through the hole.
Secure the cable connection in the hole
[
Figure
22].
5 | Installation