4.7 Troubleshooting
Error
System cannot be
switches on
System does not
switch on automatically
Suction power
too low
Suction power
too high
System does not clean properly or at all
When cleaning the filter, dirt particles come out
of the system or the collection element
Dirt particles come out of the air outlet
Status
Possible cause
Operation not light up
Power plug not plugged in
No voltage on the socket
Operation light up
FI or controller on fault
Operation not light up
Power plug not plugged in
No voltage on the socket
Sensor cable not connected
Operation light up
FI or controller on fault
Sensor cable not connected
Sensor cable not connected
to ground cable
Filter not light up
Potentiometer set too low
Lid not closed correctly
FI runs in emergency program
Potentiometer defect
Filter full
Differential pressure switch defect
Kink or damage in the flex hose
Filter light up
Filter full
Filter not light up
Potentiometer set too high
FI runs in emergency program
Potentiometer defect
Filter light up
Differential pressure switch defect
Compressed air not connected
Pressure set too low
Filter incorrectly installed
Filter element bonded
Differential pressure switch defect
Solenoid valve defect
Pressure set too high
Central screw plug loose
Filter incorrectly installed (diagonally)
Filter damaged
Filter incorrectly installed (diagonally)
Filter element missing
4.0 Mainenance and care
Troubleshooting
Plug in power plug
Apply voltage
Pull out power plug for 1 min.
Plug in power plug
Apply voltage
Connect sensor cable
Pull out power plug for 1 min.
Connect sensor cable
Connect the sensor cable
to the ground cable
Adjust potentiometer higher
Close the lid correctly
Pull out power plug for 1 min.
Replace potentiometer
Replace filter
Replace differential pressure switch
Replace flex hose
Replace filter
Adjust potentiometer lower
Pull out power plug for 1 min.
Replace potentiometer
Replace differential pressure switch
Connect compressed air
Increase pressure (max. 75psi)
Insert filter correctly
Replace filter element
Replace differential pressure switch
Replace Solenoid valve
Reduce pressure
Verschlußschraube fest drehen
Insert filter correctly
Replace filter
Insert filter correctly
Insert filter element
17