M
200D
INIVAC
3.1 Position of the control panel
The control element with the illuminated pushbuttons is located on the back of the unit to the right of the air outlet openings.
The control panel differs depending on the model and equipment
3.2 Function overview of the control element
START button (green)
BETRIEB
Control light operation
STOP button (red)
STÖRUNG
Control light malfunction
Filter reset button (yellow)
FILTER
Control light filter change
WECHSEL
Potentiometer
Vacuum power
3.3 Turning on the extraction system
The system is started with the Start button and this is indicated by the integrated Operation indicator lamp; if a sensor or remote
start cable is connected and started via this, this is also indicated by the Operation indicator lamp. The system starts automatically
as soon as the connected sensor cable sends a signal to the system.
3.4 Turning off the extraction system
The system is always stopped with the Stop button. Pressing the Stop button also deactivates the automatic start/stop function
when the sensor cable is connected and any cleaning of the filters that is currently running. If the integrated control lamp Fault
lights up, a fault has occurred. The fault is then reset by pressing the Stop button. The reset process takes approx. 3 seconds.
After the reset process has been completed, the system can be restarted.
3.5 Filter change indicator
The filter change indicator lights up if the filter is so heavily soiled that the minimum air volume flow is no longer achieved or is
undercut. At the same time, an acoustic signal sounds to alert the user that the filter must be changed. The filter change indicator
of all units is memorizing, i.e. after switching off the unit the filter change indicator and the acoustic signal remain switched on.
The acoustic signal switches off automatically after approx. 1 minute after the system has been switched off, the indicator light re-
mains on until the Filter change reset button is pressed. For systems with self-cleaning, you can try to clean the filter by additional
cleaning so that the minimum air volume flow is no longer undercut, otherwise the filter element must be replaced.
Cleaning can be started by pressing the filter change reset button for 3 seconds. The manually triggered cleaning runs for approx.
15 minutes and deactivates itself after expiration.
3.6 Potentiometer extraction power level
Potentiometer is used to set the suction power. In the case of systems with suction capacity readjustment, it is used to set the
value to which the system is to be adjusted. To deactivate the suction capacity readjustment, press and hold the start button
for 3 seconds.
Starts the system. (Green control lamp lights up). For systems with automatic suction
power control, the control can be switched of by pressing the button for 3 seconds.
Stops the system. If the integrated control lamp lights up, a fault has occurred.
To reset the fault, press the STOP key
Used to reset the filter change indicator. By pressing for 3sec the Filter Reset button,
the automatic self-cleaning of the filters is activated for 15min.
Used to adjust the suction power. For systems with suction capacity readjustment
the value to which the system is to be adjusted is set.
3.0 Operating the extraction system
A
Minivac
200D
F UM TOR
Störung
Filterelement
Filter
Antrieb
fehlt
FILTER
BETRIEB
STÖRUNG
WECHSEL
START
STOP
RESET
FILTER
®
bsaugtechnik
SAUG
LEISTUNG
15