Operation
Safety
Danger due to incorrect operation and incorrectly performed work.
This can result in serious injury and damage to property.
▶
▶
▶
Danger from escaping shielding gas
Serious personal injury of property or even danger of suffocation can be the re-
sult.
▶
Shielding gas
-
supply require-
ment
NOTE!
In order to achieve the maximum possible value for the gas flow to be reached
by the Digital Gas Control, stick to the following instructions:
▶
▶
▶
▶
22
WARNING!
All the work and functions described in this document must only be carried
out by Fronius service technicians.
Read and understand this document.
Read and understand all the Operating Instructions for the system compon-
ents, especially the safety rules.
WARNING!
Do not exceed the inlet pressure value detailed below.
Maximum inlet pressure: 7 bar (101.49 psi.)
Open the pressure reducer - if available - wide after having connected the
gas hose.
The pressure reducer with gauge tube (article number: 43,0011,0008) is not
suitable, since it does not allow for a sufficient inlet pressure.
If two or more optional Digital Gas Controls (e.g. for TimeTwin Digital) are
used simultaneously, only connect one wire feeder each to a gas cylinder or a
to a closed circuit line outlet.
The requested gas flowrate is individually adjustable for each type of materi-
al. The requested gas flowrate setpoint is specified by the "GAS" parameter.