5. Steps before using
5.1. Connection of test leads
CAUTION!
Note on using the supplied safety test leads according the IEC / EN
61010-031:2008:
Measurements in the field of overvoltage category CAT I or CAT II can be
performed with test leads without sleeves with a maximum of up to 18mm
long, touchable metallic probe, whereas for measurements in the field of
overvoltage category CAT III or CAT IV test leads with put on sleeves,
printed with CAT III and CAT IV must be used, and therefore the touchable
and conductive part of the probes have only max. 4mm of length.
The supplied test leads can be used for measurements up to 1200 V.
High-voltage measurements should be done with care and in presence of
a person, who is educated in first-aid.
Caution!
The max. input voltage for this instrument is 600 V DC/AC and to be on
the safe side, these values mustn´t be passed. The max. voltage-
difference between COM-input and earth is 600 V DC/AC
. Higher
eff
voltage-differences may cause personal injury or damage of the unit.
5.2. Angle position of the unit
This multimeter is provided with a stand at it´s backside for having and
angle-position.