2.5.5.Restoring the original configuration
CAUTION
Only switch off power (double cut-out) for the motorised product to be reset.
NOTICE
This reset deletes all the local control points, all the sensors.
1] Position the motorised product at the mid-height position.
2] Cut the power supply for 4 seconds.
3] Switch the power supply back on for 5 to 15 seconds.
4] Cut the power supply for 4 seconds.
5] Switch the mains power supply back on:
ð The motorised product moves for a few seconds. (If the motorised
product is in the upper or lower limit position, it will briefly move up and
down).
6] Press the PROG button on the Somfy local control point for ≈ 7 s until the
motorised product moves up and down twice:
g The drive is reset to the original configuration.
Repeat the commissioning procedure (see the section entitled Commissioning).
3.USE AND MAINTENANCE
NOTICE
This drive does not require any maintenance operations.
3.1.Up, Down and Scroll buttons
1] To move back or forth, briefly press the Up or Down button.
2] To tilt the slats, press and hold the Up or Down button or use the scroll of
the remote control, until the slats reach the desired position.
3.2.My button
3.2.1.Stop function
The motorised product is moving:
Press the my button: the motorised product stops.
3.2.2.Favourite (my) position
NOTICE
• A 50% open position, referred to as the "my" position other than the fully up or fully down position, is
programmed by default in the drive.
• The product adjusts its end limits before reaching the "my" position.