Ventilation
UV radiation
X
Dry and clean
environment
Maintenance/Cleaning
Water (≤ 30°C)
Mild detergent
Gentle hand
washing
If it deems necessary, rinse the Cobra
buckles of treeMOTION USCA with
lukewarm water. After drying put one
drop of WD40 on each moving / mov-
able part of the buckle.
Drying
Hang in well ventilated space (≤ 30C)
Direct sunlight
X
Applied heat (e.g. fire)
X
Disinfection
Water (≤ 30°C)
Ethanol
Corrosive substances
Keep away from corrosive acids, bases,
liquids, vapours, gases etc. Be careful
with tree exsudates! They may be sur-
prisingly aggressive. If you think damage
has occurred as a result of contact with
an agressive substance:
1. Quarantine the product and label it
in an obvious way so that it can not
be used by mistake;
2. Send as much detail as possible
about your concerns to the manu-
facturer;
3. Do not use the product again unless
the manufacturer replied (in writing)
Excessive moisture
X
+15°C to +25°C
Sharp edged
X
objects
Machine washing
X
Pressure washer
X
Duration (≤ 1 hour)
Rinse after
disinfection
that it may be returned to service.
WARNING
If any part of the harness is to be exposed
to chemicals, e.g. cleaning materials or
hazardous atmospheres, the user should
consult the manufacturer before to de-
termine whether the part is suitable for
continued use.
8. REGULAR CHECKS
Checking the equipment at regular inter-
vals is absolutely necessary: your safety
depends on the effectiveness and dura-
bility of the equipment!
Following each use, the product should
be checked for abrasion and cuts. Also
check it for the legibility of the product
labelling! The use of damaged compo-
nents or components subjected to a fall
must be discontinued at once. If there
is only the slightest doubt, the product
needs to be retired or subjected to testing
and by a competent person.
When using the equipment in occupation-
al health and safety to EN 365, it must
be checked at least every 12 months and
when using to AS/NZS 1891.1 at least
once every 6 months by a duly qualified
person strictly observing the instructions,
or else by the manufacturer, and it must,
whenever necessary, be replaced. These
inspections must be documented (doc-
umentation of equipment; cf. following
table). Refer to national regulations for
inspection intervals.
This inspection must comprise:
– Inspection of the general condition:
age, completeness, dirt, correct
composition.
– Inspection of the labels: Present?
ReGULaR checks