will be delayed to the next cycle: in this case, the hot tub water
quality could worsen, since the filtering cycle time was reduced.
Do not program too long time periods that could signifi-
cantly reduce the filtering cycle time: the water must always
circulate through the filter.
NOTES
- Warning: only a normally open (not closed) contact must be con-
nected to the terminal provided on the electrical box.
- It is advisable to program the "silence" function so that it does not
coincide with the filtering cycles.
- If the pump and/or blower are operating when the "silence" func-
tion should start, it is suspended and then resumed for about one
minute after the pump and/or blower are switched off.
- If a new temperature value is set during the "silence" function, this
will be valid at the end of the function.
K
EYBOARD LOCK
To avoid accidentally modifying the set parameters, there is an op-
tion to activate the keyboard lock function.
To enable this function, simply press the keys below at the
same time and hold for approximately 3-5 seconds:
The message "Loc" appears (followed by the water temperature).
NOTE
- When the display is locked, the pumps, spotlight, etc. cannot be
activated; however, the round displays can be used for activating
the various functions.
- The "keyboard lock" function cannot be activated on
round displays.
To disable the keyboard lock, simply press these same keys at
the same time for approximately 3-5 seconds (the water temper-
ature is displayed).
Abnormal operating conditions
Messages and alarms on the display
Messages or alarms are indicated on the display with the corre-
sponding error code.
Jacuzzi Europe S.p.A. © 2023
~ 3-5"
36
You will continue to see the code if the alarm condition persists.
Note: please also see the chapters describing the different functions.
Signals on display
- possible solution
"L1" This appears when the hot tub is turned on if the water level
in the tank is not sufficient (the pumps cannot be activated).
- Add water to the hot tub until the message disappears.
"L2" The water level in the balance tank is not sufficient.
- The solenoid valve is activated; once the correct level has been
reached, the message disappears.
"AL1" The tub has not reached the correct fill level in the preset
time (60 mins); the pumps cannot be activated.
- Turn the switch on the main power supply line to the hot tub
off and on again; if the problem persists, contact an authorised
Jacuzzi® service centre.
"AL2" The balance tank has not reached the correct fill level in
the preset time (60 mins).
- Check the solenoid valve and pipework; if the problem persists,
contact an authorised Jacuzzi® service centre.
"LL" The water level in the tank is not sufficient (the pumps can-
not be activated).
- Add water to the hot tub until the message disappears.
"ICE" the "Smart winter" function is active (anti-freeze, please
see relevant chapter)
- You do not need to take any action.
"CO" the spotlight control system does not work
- Contact an authorised Jacuzzi® service centre.
"FLO" The flow switch does not detect the water flow (heating
cannot be turned on).
- check that dipswitch no. 8 is set to OFF (see the "Electrical con-
nections and safety" chapter).
- Flow switch may be faulty; contact an authorised Jacuzzi® ser-
vice centre.
"FLC" The flow switch shows the water flow when the filtering
pump is off
- Flow switch may be faulty; contact an authorised Jacuzzi® ser-
vice centre.
"Er" Water temperature beyond the range managed by the sys-
tem or faulty temperature probe.
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 45 °C (111 °F) or it
has dropped below 5 °C (41 °F). It is no t possible to turn any func-
tion on.