Herunterladen Diese Seite drucken

Bosch Rexroth PSI 6xCx.179 Anleitung Seite 37

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

R911174862 | PSI 6xCx.179
Electrode tip dress:
7
Features
Sequence standard 1000 Hz (sequence parameters in milliseconds)
I/O board : E/A_DISKR2ED
(Details refer to Tab1. Required and supplementary documentation,
Rexroth PSI6xxx Weld Timer with Medium-Frequency Inverter Instructions).
7.1
Special features
The welding controller features the following specifics:
• Control preferable for hanging stations with 2 starts/2 electrodes and 4
programs each
• Weld Control is prepared for the control system PSQ6000 XQR.
• Control is prepared for a networking with Ethernet.
• The fault: "External 24V is missing" stop is automatically confirmed.
• A check of the pressure feedback at the end of the squeeze time is selectable.
• The mains voltage is always checked, the error message: Synchronization fault,
is self acknowledging.
• The gun is expected in retract open position when the weld control is switched
on.
At first the retract close signal is necessary to assure a defined gun position
and to avoid the program start with magnet valve closing in retract open
position of the gun which would be dangerous for the process.
• The program selection and the analog pressure output will be updated as soon
as there is a change in one of the inputs "Gun X_Program_Y", "Initiator Tip
dress" or "Individual Tip dress" , not only with the next start of a weld schedule.
The program selection is related to the gun which was last started.
• The gun delay times T_delay and T_delay_schedule, which are mentioned in
the folowing diagrams are programable.
• When Lamp test is selected, Lamp test activates the following outputs:
-
Timer control ready
-
- Timer control fault
-
- Weld fault
-
- Tip dress request 1
-
- Tip dress request 2
-
- Tip life Warning/Exp 1
-
- Tip life Warning/Exp 2
-
- UI-regulation active
• With cooling fan supply on X4/13-14
-
"Fan On ", if cooler temperature is > = 55 º C
-
"Fan Off ", if cooler temperature is < = 40 º C
7.1.1
Electrode care concept
The electrode care concept has got separate in-and outputs for electrodes No. 1
and electrodes No. 2.
If the electrode is in status "pre warning" the output "GunX Pre-Warning / Life
Expired" is flashing.
If the electrode is in status "Tip life expired" the output "GunX Pre-Warning / Life
Expired" is set continuously.
At "Tip Dress Request" the output "GunX Tip Dress Request" is flashing.
At "Tip Dress - Stop" the output "GunX Tip Dress Request" is set continuously.