Installation and connection
e
Product can only be installed and connected
in accordance with the statutory installation
rules.
So not install the hob on places with sharp
edges or corners.
"There is the risk of breaking for glass
ceramic surface!
Electrical connection
Connect the product to a grounded outlet/line
protected by a fuse of suitable capacity as stated
in the "Technical specifications" table. Have the
grounding installation made by a qualified
electrician while using the product with or
without a transformer. Our company shall not be
liable for any damages that will arise due to
using the product without a grounding installation
in accordance with the local regulations.
\ The product must be connected to the
mains supply only by an authorised and
qualified person. The product's
warranty period starts only after correct
installation.
Manufacturer shall not be held responsible
for damages arising from procedures
carried out by unauthorised persons.
The power cable must not be clamped,
bent or trapped or come into contact
with hot parts of the product.
A damaged power cable must be replaced
by a qualified electrician. Otherwise, there is
risk of electric shock, short circuit or fire!
e
Connection must comply with national
regulations.
e
The mains supply data must correspond to
the data specified on the type label of the
product. Type label is at the rear housing of
the product.
e
Power cable of your product must comply
with the values in "Technical specifications"
table.
10/EN
Before starting any work on the
electrical installation, disconnect the
product from the mains supply.
There is the risk of electric shock!
Connecting the power cable
1. If itis not possible to disconnect all poles in
the supply power, a disconnection unit with
at least 3 mm contact clearance (fuses, line
Safety switches, contactors) must be
connected and all the poles of this
disconnection unit must be adjacent to (not
above) the product in accordance with IEE
directives. Failure to obey this instruction
may cause operational problems and
invalidate the product warranty.
Additional protection by a residual current circuit
breaker is recommended.
i a cable is supplied with the product:
L1 BLACK
L2 GRA Y 3%
NEUTRAL
BLUE "RSS
© < Rem
EAR
TH YEL-GRN
||
SX1.5mm 2
400V 2N ~
2. For single-phase connection, connect the
wires as identified below:
Brown/Black cable = L (Phase)
Blue/Grey cable = N (Neutral)
e _ Green/yellow cable = (E) = (Ground)
3. For double-phase connection, connect the
wires as identified below:
Brown cable = L1 (Phase 1)
Black cable = L2 (Phase 2)
Blue/Grey cable = N (Neutral)
e _ Green/yellow cable = (E) == (Ground)
» Or
e
Black cable = L1 (Phase 1)
e
Grey cable = L2 (Phase 2)
e
Blue/Brown cable = N (Neutral)
e _ Green/yellow cable = (E) == (Ground)