Description of the functions
Stagnation rinse:
DIP switch 6
Serves to remove stagnant water that accumulates during longer periods of
disuse.
DIP switch 6 ON = Stagnation rinse function enabled.
DIP switch 6 OFF = Stagnation rinse function disabled (default setting).
Time interval
Can be set from 3–48 h at the
interval control (see p. 23).
3–48 h
60 cm
60 cm
60 cm
60 cm
PROOF P6 with thermal disinfection
Automatic stagnation rinse
If the fitting has not been used
for the set period, the stagnati-
on rinse operation is automati-
cally executed for 10 s.
SanTec OCEAN P6 with thermal disinfection
Shower control
ON
OFF
1 2 3 4 5 6
Safety
If the cleaning stop function is
enabled, the stagnation rinse
function will only start 2 min
after the cleaning stop function
has been disabled.
10 s
EN
Warmlauf:
ON
OFF
1 2 3
4
5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
Halbautomatik:
ON
OFF
1 2
3 4 5 6
Vollautomatik:
ON
OFF
1 2
3 4 5 6
Manuell:
ON
OFF
1 2
3 4 5 6