English
11. Place the UltraVent on the frame
[
Figure
13].
>
Only place the UltraVent on the
frame if the electrical compartment
is closed [
>
Ensure that none of the cables are
crushed [
lugs of the frame and the UltraVent
are positioned above the mounting
holes [
Figure
12. Screw the UltraVent to the frame
[
Figure
14].
13. Mount the suitable cover plate
[
Figure
15].
14. Open the left side wall of the unit
[
Figure
16].
15. Loosen the fastening of the safety
temperature limiter [
>
Carefully set the safety temperat-
ure limiter to one side.
16. Break out a hole in the rear wall of the
electrical compartment.
17. Guide the BUS cable and the shielded
cable through the hole and fasten the
PG screw connection.
18. UltraVent XS – year of manufacture
until 01/2023 [
Plug the control cable into a free BUS
interface of the fan motor
[
Figure
18].
Units until 20/03/2023:
Plug the control cable into a free bus
interface of the fan motor (1).
Important:
If the UltraVent XS (year of manufac-
ture until 01/2023) is installed on a
unit with year of manufacture from
03/20/2023, a BUS translator must
be installed (Item number:
87.01.966S).
14 / 108
Figure
10].
Figure
11] and that the
12].
Figure
17].
Figure 18
]:
80.51.597_iCombiPro-iCombiClassic_IntegrationKit_IM_EU-west
UltraVent XS – year of manufacture
from 02/2023 [
Disconnect the termination resistor
(white connector) from the bus inter-
face (2). The connector is part of the
wiring harness and can be left hanging
freely.
Plug the control cable into a free bus
interface of the fan motor.
19. Fix the cable to the rear side of the unit
with the self-adhesive cable clips sup-
plied.
20. Connect the shielded cable to the
steam generator housing with the
ground connection [
21. Mount the fastening of the safety tem-
perature limiter.
22. Close the left side panel.
23. Slide the pre-assembled tower into the
middle of the installation cabinet.
>
Do not push the tower completely
into the installation cabinet yet to
make the installation of the side
panels easier.
24. Mount the side panels on the left and
right [
Figure
25. Push the pre-assembled tower into
the final position [
26. Unlock the front end of the UltraVent.
[
Figure
23]
27. Hook in the front end of the UltraVent
and lock the front end [
28. Fasten the perforated plate at the bot-
tom with the filter fastening
[
Figure
22].
29. Mount the type plate.
4 | Installation
Figure
18]:
Figure
19].
20].
Figure
21].
Figure
22].