12.14 Sloping terrain in the mowing
area
Note:
For a robust installation, it is
recommended to route the
perimeter wire on a maximum
incline of +/- 10° (17%). The wire
can be routed on an incline of up to
+/- 15° (27%), however this can
significantly increase the effort and
level of adjustment involved in
routing the wire. Inclines should
also always be noted in garden
sketches.
In order for the robotic mower to
automatically mow a slope in the mowing
area (up to 15° incline) trouble free, the
perimeter wire must be installed in the
slope with a minimum clearance to the
edge of the incline.
A clearance of at least 100 cm must be
observed for water features and sudden
drops like edges and steps.
Slope with an incline of 5° - 15°:
If there is a slope with an incline of 5° - 15°
in the mowing area, the perimeter wire can
be routed past the top edge of the slope in
the slope as shown. The minimum
clearance (0,5 m) from the top edge of the
0478 131 9942 C - EN
slope to the perimeter wire must be taken
into account for trouble-free operation of
the robotic mower.
Slope with an incline > 15°:
If there is a slope with an incline > 15° in
the mowing area, it is recommended that
the perimeter wire (1) be routed in the flat
area before the top edge of the slope. The
top edge and area of the slope are not
mown.
12.15 Installing reserve wire
Reserve wire installed at regular intervals
makes it easier to make any necessary
corrections such as subsequently
changing the position of the docking
station or the routing of the perimeter wire.
In particular, reserve wire should be
installed near difficult passages.
Route perimeter wire (1) as illustrated
between 2 fixing pins spaced approx. 1 m
apart. Attach the reserve wire to the
ground in the centre using a further fixing
pin.
12.16 Using wire connectors
In order to extend the perimeter wire or to
connect loose wire ends, only the gel-filled
wire connectors available as accessories
may be used. They prevent premature
wear (e.g. corrosion of the wire ends) and
ensure optimal connections.
Make a note of the positions of the wire
connectors on the sketch of the mowing
area. (
12.2)