Description of the device
For the illustrations, refer to the graphics page
Illustration A
Locking filter cover
1
Filter cover
2
Power switch
3
CO
connection
4
2
Water connection
5
Power supply
6
Fuse holder cover with 6 A fuse
7
Type plate
8
Air vents
9
Combined Filter
10
Filter holder
11
Button for "CO
chilled water"
12
2
Button for "Chilled water"
13
Water dispenser opening
14
Drip tray
15
Installation
Connecting the device
During initial installation and any repairs that involve the
replacement of accessory parts, make sure only parts
approved by KÄRCHER (connection kit, CO
regulator) are used. These components have been test-
ed and certified to ensure compliance with KÄRCHER
Quality Standards. No other components may be used.
● The power connection and water input pressure
must correspond to the values in the technical data
(see chapter "Technical data").
● Depending on local regulations, an approved back-
flow preventer must be installed.
● Set up the device on a level surface.
● Mains plug and socket must always be freely acces-
sible.
● The trigger, the fuse and the gas and water connec-
tion (rear of the device) must be freely accessible.
The minimum distance to the wall is 100 mm.
● In the interest of reducing power consumption, the
power supply can be switched off when the device
is not in use (e.g. using a timer clock).
● Connect the device only with the hose lines provid-
ed.
● Do not use used hose lines.
Connection diagram:
Illustration B
Socket (fused with 30 mA error-current circuit
1
breaker)
Mains cable
2
Water dispenser
3
Water supply hose (connection kit)
4
Pressure reducer with pressure gauge (only neces-
5
sary with water inlet pressure above 6 bar (0.6
MPa))
Water tap of the building installation
6
Drinking water line of the building installation
7
Aqua stop (optional)
8
Backflow preventer (optional)
9
Connections:
Illustration C
Water connection
1
CO
connection
2
2
Power supply
3
Fuse holder cover with 6 A fuse
4
Illuminated trigger
5
1. Remove the plug from the water dispensing opening
and dispose of it.
Illustration D
2. Remove the plugs from the water connection and
the CO
connection and dispose of them.
2
Illustration E
3. Connect the water supply hose to the water connec-
tion "H
O".
2
4. Connect the water supply hose to the tap of the
building installation (if necessary, connect additional
components).
5. Connect the mains cable to the power supply.
6. Connect the CO
2
nection.
Inserting the filter
WARNING
Health risk through the entry of germs
When installing the filter cartridge, take special care to
ensure hygiene and cleanliness.
Always wear sterile disposable gloves when installing
the filter.
1. Open the filter cover latch.
Illustration F
2. Remove the side filter cover.
3. Remove the service cup that was installed at the
factory.
Illustration G
a Pivot out the filter holder by max. 45°.
b Turn the service cup anticlockwise.
c Remove the service cup.
4. Insert the filter.
Illustration H
a Pivot out the filter holder by max. 45°.
b Insert the filter into the filter holder from above.
c Turn the filter as far as it will go.
The filter is locked.
d Pivot the filter with the filter holder into the device.
5. Fit the side filter cover.
6. Close the filter cover latch.
Initial Start-Up
Note
In order to maintain the perfect hygienic condition of the
device, the water-carrying components were filled with
pressure
2
nitrogen at the factory.
Before the device can be rinsed with water, the nitrogen
filling of the CO
mixing container must first be rinsed
2
out. This should be done with CO
Rinsing the CO2 mixing container
1. Connect a CO
bottle or a new CO
2
chapter " Connect the new CO
ing a new CO
cylinder").
2
2. Set the CO
pressure:
2
a CO
bottle: Open the main valve and set the ro-
2
tary control so that the pressure gauge shows
4 bar.
b CO2 cylinder: Turn the adjustment wheel of the
rotary control to position "4".
3. Switch the device on.
4. Keep the water inlet closed.
5. Place a container under the water dispensing open-
ing.
6. Press the "CO
chilled water" button for 10 seconds.
2
Some gas will escape that might be mixed with
drops of water. This brief escape of gas is not dan-
gerous.
7. Turn the rotary control to 0 bar or position "0".
8. Press the "CO
chilled water" button until no more
2
gas can be heard.
Rinsing the device and filter
Note
Now the entire device and the filter are rinsed with wa-
ter.
1. Open the water inlet.
2. Place a container under the water dispensing open-
ing.
3. Press the "chilled water" button repeatedly until the
rinsing time is 5 minutes (approx. 10 – 15 litres).
4. Press the "CO
chilled water" button repeatedly until
2
the rinsing time is another 4 minutes (approx. 4 –
5 litres).
Note
After every 60 seconds of uninterrupted water delivery,
the device automatically interrupts the delivery.
5. Perform chemical cleaning (see chapter " Chemical
cleaning").
6. Set the CO
pressure:
2
a CO
bottle: Open the main valve and set the ro-
2
tary control so that the pressure gauge shows
4 bar.
b CO2 cylinder: Turn the adjustment wheel of the
rotary control to position "4".
The appliance is ready for operation.
Handling the CO
Note
Please also note the general information on handling
CO
bottles, see chapter General instructions for han-
2
dling CO
bottles.
2
When connecting a new, or removing an old CO
follow the steps below.
English
connection hose to the CO
con-
2
gas.
2
cylinder (see
2
bottle" or " Connect-
2
bottle
2
bottle,
2
Removing an empty CO
Illustration I
Rotary control
1
Pressure reducer
2
Union nut
3
Main tap
4
Control pressure gauge
5
CO
hose
6
2
1. Close the gas bottle at the main tap.
2. Turn the pressure regulator to "0".
Note
If the pressure reducer is separated from the CO
when sufficient pressure is still present, the O-ring be-
tween the bottle and the pressure reducer will be de-
formed and must be replaced.
3. Release the strap securing the CO
4. Remove the empty gas bottle.
5. Unscrew the pressure reducer from the empty gas
bottle.
Connect the new CO
Illustration I
Rotary control
1
Pressure reducer
2
Union nut
3
Main tap
4
Control pressure gauge
5
CO
hose
6
2
1. Remove the protective cap from the new gas bottle.
2. Open the main tap briefly so that any liquid CO
escape.
3. Screw the pressure reducer onto the new gas bottle.
Ensure that the sealing ring is seated properly.
4. Tighten the union nut hand-tight.
5. Fit the new CO
bottle and fasten it with a tension
2
belt.
6. Connect the CO
hose to the pressure reducer.
2
7. Slowly open the main tap on the gas bottle.
8. Set the pressure reducer to 4 bar using the rotary
regulator.
9. Close the main tap on the gas bottle.
10. Read off the displayed value on the control pressure
gauge. The displayed value must remain constant
for at least 5 minutes.
If there is a noticeable drop in pressure:
11. Eliminate the pressure drop.
a Check that the O-ring between the compressed
gas tank and the pressure reducer is present and
undamaged.
b If necessary, replace a defective O-ring.
c Check the pressure reducer for correct seating.
d Tighten the union nut more firmly.
e Check the hose coupling on the pressure reducer
and the CO
hose for visible damage.
2
If the pressure drop cannot be remedied by the meas-
ures mentioned, the pressure reducer is defective and
must be replaced.
12. After passing the leak test, open the main tap.
13. Set the operating pressure on the pressure reducer
using the rotary control. The default setting is 4 bar
and can be readjusted if necessary.
14. After each renewal of the CO
bottle, dispense one
2
litre of "CO
carbonated water" so that the CO
2
fills again.
Handling the CO
2
Note
Please also note the general information on handling
CO
bottles, see chapter General instructions for han-
2
dling CO
bottles.
2
Note
CO
Cylinders are available in pharmacies, electronics
2
stores and supermarkets.
When connecting a new or removing an empty CO
inder the following steps are to be carried out.
Removing an empty CO
Illustration J
Pressure regulator scale
1
Adjustment wheel
2
Pressure regulator
3
Screw connection
4
CO
hose
5
2
bottle
2
bottle
2
bottle.
2
bottle
2
can
2
mixer
2
cylinder
cyl-
2
cylinder
2
13

Werbung

loading