Additional fan
External hardware is connected via the Miele XCI box.
If an extra fan is connected, it must be switched on at the same time as the drive unit.
- Off
- On
Pressure sensor
External hardware is connected via the Miele XCI box.
When using a shared exhaust air duct, one tumble dryer may have to be switched off or
suppressed from the outset if certain pressure levels have built up in the ducting. Be-
cause the pressure sensor is an external unit, there is the option of reading in both a lo-
gical normally open contact or a normally closed contact.
A message appears in the display while the exhaust air flap is open.
- Off = Not active
-
NO contact
= Active
Responds to high potential
NC contact
-
= Active
Responds to low potential
Peak load signal
External hardware is connected via the Miele XCI box.
The peak-load negotiation function enables the tumble dryer to be connected to an en-
ergy management system. When a signal is registered, the tumble dryer's heater is
switched off for a short period or the appliance is prevented from being switched on.
The tumble dryer may only be operated with a peak-load system if this system is connec-
ted to the tumble dryer via the Miele XCI box.
- Factory default: no function
- Peak load with 230 V
- Peak load with 0 V
Peak load prevention
With this function, the application of a hygiene programme is not amended when a peak
load signal is in place. The heater stays switched on.
- Factory default: Off
- On
COM module selection
This tumble dryer is equipped with an integrated WiFi module. However, the dryer can
also be equipped with an external module.
- Off