Changing this setting leads to increased energy consumption.
- Factory default: off
- On
Cooling down temp.
The laundry will be cooled down automatically before the end of the programme. The
automatic cooling-down phase which takes place before the end of a programme can be
set at a cooler level for all programmes. This means that the cooling phase is extended.
Changing this setting leads to increased energy consumption.
The setting can be changed from 40 °C–55 °C.
Factory default: 55 °C
Fan pulsed operation
The fan operates intermittently to release laundry that is stuck in front of the inner drum
door. With heat-pump dryers, the fan function operates intermittently to dry duvets.
The fan is switched on and off at certain intervals.
Service
Clean out the airways
The tumble dryer's electronics calculate the degree at which fluff or detergent residue in
the fluff filters and air ducts are impairing performance. A message to check the contam-
ination appears. You can decide at what level of fluff this reminder should be emitted.
This prompt, which you can configure, is displayed:
filter.
- Off
The reminder does not appear. However, if there is a very severe blockage in the ducting,
the programme will be cancelled and the reminder will appear in the display regardless of
this option.
- Heavy
The reminder only appears when there is a heavy build-up of fluff.
- Factory default: normal
- Sensitive
The reminder appears when there is only a small build-up of fluff.
Clean the filters
The fluff filter in the air duct area must be cleaned on a regular basis. You can set an
hourly interval for the reminder.
The selected hourly interval depends on how much fluff tends to build up and how often
you wish to clean the filter, e.g. for hygiene purposes.
You can adjust this reminder:
- Time interval of 5–55 hours
- Factory default: after 55 hours
Clean the filters
en - Supervisor level
Clean the fluff filter and rinse the plinth
107