The date can be shown starting with the day, month or year.
- Date
The date is set.
Volume
The volume for various sounds can be changed.
The volume can be changed.
- Finish tone
- Keypad tone
- Welcome tone
- Fault alarm
The acoustic signal that indicates a fault can be switched off. The volume cannot be
changed here.
Res. moisture display
In addition to displaying the drying level, the residual moisture can also be indicated as a
percentage.
- Factory default setting: Without % value
- With % value
Visibility parameters
Various parameters are offered/displayed when a programme is selected. You can decide
which parameters should not be displayed. These parameters can then not be edited dur-
ing programme selection.
- Residual moisture
- Duration
- Low temperature
- Anti-crease
- Load size
- Drying temperature
"Display" off status
The display switches off to save energy; only the Start/Stop sensor flashes slowly. You
can change this setting.
Changing this setting leads to increased energy consumption.
-
Off
No switching off
On (10 min.) Not curr.prog.
-
The display will remain on during the programme sequence but will go out 10 minutes
after the end of the programme.
en - Supervisor level