Save as
The
menu opens.
Use the letters and symbols below the line to enter the name.
Save
Touch the
sensor control.
You can now enter the parameters for a Res. moisture programme or Timed drying.
The 5 special programmes are pre-programmed at the factory. You can change these spe-
cial programmes.
The special programmes are added to the programme packages. Enter the name and set-
tings of your special programme into the "Special programmes" table in the "Programme
overview" chapter.
Res. moisture programme
Final residual moisture
-
-6 % (dry) – 40 % (damp)
-
Extra drying time
:
0–60 minutes
Temperature
-
(Process air):
cold – 60 °C
Cooling down temperature
-
40–55 °C
-
Anti-crease
Drum rotation, main direction
–
0–500 seconds
Pause
–
:
100–3000 seconds
Drum reversal
–
0–500 seconds
Timed drying
:
Running time
-
:
1–120 minutes
Temperature
-
(Process air):
cold – 60 °C
Cooling down temperature
-
40–55 °C
Anti-crease
-
Drum rotation, main direction
–
0–500 seconds
–
Drum reversal
0–500 seconds
Pause
–
:
100–3000 seconds
:
:
(Process air):
:
:
(Process air):
:
:
en - Supervisor level
105