sub-display, the MAX-value on the right sub-display. On the middle
sub-display the average value = AVG is shown. This value is currently
"refreshed".
To exit this function mode press SET/R again or press FUNC or turn the
rotary function switch (observe the safety rules!), afterwards return
to normal settings.
e) REL (= Relative)
The relative mode enables the operator to compare the reference
value with a subsequent reading. Proceed as follows:
- Set the function mode at REL mode and press once the button SET/R
- Store the polarity by pressing the UP and DOWN keys, afterward press
SET/R button.
- Press UP and DOWN buttons again to set the desired reference value.
Press SET/R by turns to move to the next digit.
- For final setting of the reference value press SET/R button once again.
- The meter will now display the difference between the stored refe-
rence value and the subsequent readings on the sub-displays, while
the present (true) measurement is on the main-display. The left sub-
display will show the difference in %, the middle sub-display will
show the offset and the right sub-display the preset reference.
To exit this function mode press SET/R again or press FUNC or turn the
rotary function switch (observe the safety rules!), afterwards return
to normal settings.
f) MEM (= Memory)
Up to 10 measurements (reference number 0 to 9) can be stored and
recalled. Proceed as follows:
1. Push function button until MEM flashes in the display, afterwards press
the key SET/R once. MEM is fixed and the reference number flashes.
Make your measurements and push the SET/R key once to store the
present measurement value in the first free memory location = refe-
rence no. 0.
2. Press UP/DOWN button to go to the next free memory location (refe-
rence no. between 0 and 9).
16
Make again your measurement and push the key SET/R once. This selec-
ted memory now is addressed. If a memory number which has been
used before is selcted, the previous value is updated and stored with
the new measurement value.To exit this function mode turn the func-
tion switch (observe the safety rules!) or press the buttons FUNC or
SET/R.
Hint
If you exit the function mode because you pushed the SET/R button too
often, this function mode is left, but the memory is not erased and can
be "recalled" with the following function mode.
g) RCL (= Recall)
This function enables you to get the memorized reading back on the
LCD. Follow these steps:
- Push FUNC key until RCL flashes. Push SET/R once. RCL is fixed but the
reference number flashes. Press UP or DOWN buttons to address the
desired number where the measurement has been memorized. Press
SET/R button to get the memorized value back on the display. Then
the chosen value will appear on the left sub-display. The following
memory locations are displayed in the other smaller displays. To exit
this function mode turn the function switch (observe the safety rules!)
or press the buttons FUNC or SET/R, afterwards return to basic set-
tings.
h) CMP (= Comparison)
This function mode enables you to make the High/Low comparison of
subsequent readings, by comparing a reading with both the stored
high reference value and the stored low reference value.
On the sub-display "Lo" appears for reading less than the low refe-
rence value, "Hi" is displayed for reading more than the highest refe-
rence value and "Pass" for a middle value between the low and the
high reference value.At the same time an interval signal is emitted.
To activate this function mode, push "FUNC" until the symbol "CMP
appears on the top of the display and "LOW" flashes over the left
sub-display. Now push again SET/R button and then "UP" and
"DOWN" to set the minimum reference value with polarity. Press
after each change SET/R button again, to enter the setting and to go
17