Safety Instructions - VOLTCRAFT AT-200 Bedienungsanleitung

Digital multimeter
Vorschau ausblenden Andere Handbücher für AT-200:
Inhaltsverzeichnis

Werbung

400 mA
4 A
10 A
Overload protection: µA/mA 0.5A 250V quick-acting fuse
10 A
250 V
Duration of measurement in the 10A range:
AC ampere
400 µA
4000 µA
40 mA
400 mA
4 A
10 A
Overload protection: µA/mA 0.5A 250V quick-acting fuse
10 A
10A 250 V
Duration of measurement in the 10A range:
Frequency of the alternating voltage: 50 Hz to 400 Hz
Resistance
400 W
4 kW
40 kW
400 kW
4 MW
40 MW
Overload protection: 250 V
Continuity tester: acoustic signal for resistances <150 Ω, test current: <0.3mA
Diode test
Test voltage, max. 1.5 V (max. 0.3mA)
Capacity
40 nF
400 nF
4 µF
40 µF
100 µF
Overload protection: 250 V
Frequency
5 Hz
50 Hz
500 Hz
5 kHz
50 kHz
500 kHz
10 MHz
Overload protection: 250 V
Measuring sensitivity up to 1MHz: 500 mV
> 1 MHz 3V
40
+/-(1.5%+3dgt)
0.1mA
+/-(2.5%+5dgt)
0.001 A
+/-(2.5%+5dgt)
0.01 A
quick-acting fuse
0 up to </=5 A permanent measurement
> 5A max. 30 sec with a pause of 15 min
+/-(1.5%+5dgt)
0.1 µA
+/-(1.8%+5dgt)
1 µA
+/-(1.8%+5dgt)
0.01 mA
+/-(1.8%+5dgt)
0.1mA
+/-(3.0%+7dgt)
0.001 A
+/-(3.0%+7dgt)
0.01 A
quick-acting fuse
0 up to </=5 A permanent measurement
> 5A max. 30 sec with a pause of 15 min
+/-(1.2%+4dgt)
0.1 kΩ
+/-(1%+2dgt)
0.001 kΩ
+/-(1.2%+2dgt)
0.01 kΩ
+/-(1.2%+2dgt)
0.1 kΩ
+/-(1.2%+2dgt)
0.001 MΩ
+/-(2%+3dgt)
0.01 MΩ
+/-(5%+7dgt)
0.01 nF
+/-(3%+5dgt)
0.1 nF
+/-(3%+5dgt)
0.001 µF
+/-(3%+5dgt)
0.01 µF
+/-(5%+5dgt)
0.1 µF
+/-(1.5+5dgt)
0.001 Hz
+/-(1.5+5dgt)
0.01 Hz
+/-(1.2+3dgt)
0.1 Hz
+/-(1.2+3dgt)
1 Hz
+/-(1.2+3dgt)
10 Hz
+/-(1.2+3dgt)
100 Hz
+/-(1.5+4dgt)
1 kHz

Safety Instructions

Please read the complete instructions carefully before starting
operation. The information contained is important for correct ope-
ration.
The warranty will lapse in case of damage caused by failure to
comply with these operating instructions! We shall not be held lia-
ble for any consequential damage or loss!
We do not accept any liability for personal injury or damage to pro-
perty caused by incorrect handling or non-observance of the safety
instructions! In such cases the guarantee will lapse.
This device left the factory in perfect condition in terms of safety engineering.
To maintain this status and ensure safe operation, the user must comply with the
safety instructions and warnings ("Caution!" and "Note!") contained in these instruc-
tions for use. The following symbols and notices must be observed:
Note! Read the instructions for use!
This product is CE-tested and meets the necessary directives.
Only for use in dry interior environments
Insulation class 2 (double insulated)
CAT II
Overvoltage category II for measurements at electric devices.
CAT III
Overvoltage category III for measurements of the building installation.
Earth potential
For safety and licensing reasons (CE), unauthorised conversion and/or modification
of the device is not permitted.
Consult suitably qualified staff, if you have doubts about how the equipment opera-
tes or about how to connect it safely.
Measuring instruments and accessories are not toys and have no place in the hands
of children!