4.1
OPERATING ELEMENTS AND DISPLAYS ON
DEVICE
1
Pressure regulator (Step 0-10)
2
Selector switch for operating mode
3
Indicator light (Error)
4
Operating light (Power)
5
EMERGENCY STOP switch
POWER ERROR
4
3
5
2
The pressure can be adjusted using the pressure regulator
(Fig. 3, 1):
0
1-4 (yellow area, 25 bar)
5-10 (green area, 26-120 bar) Setting of the required wor-
The corresponding colour areas and exact pressu-
re are displayed on the pressure gauge.
The selector switch (Fig. 3, 2) offers the following modes:
"F" position = Forward/Feed
Basic setting for working
0
The pump is switched on and off by pulling
and releasing the trigger guard on the gun.
„0" position = No activity
The machine is ready for operation but the
0
pump is not yet running.
"R" position = reverse gear
This setting is required for:
0
• relieving pressure on the high pressure
hose
SPEED
1
Pump switched off
Setting for pre-filling and
cleaning
king pressure (max. 120 bar)
Detailed explanation of selector switch use:
If the selector switch is in position "F", the PC HP 30 can be
switched on and off using the trigger guard on the spray gun.
The operating light (green, Fig. 3, 4) indicates that the ma-
chine is energised and ready.
When the mains plug is connected the PC HP 30 carries out a
function check. While this is going on the indicator light (red,
fig. 3.3) flashes. If everything is in working order, the flashing
stops after about 30 seconds. If the indicator light lights up
during operation, this indicates that there is a malfunction. For
detailed information about this kind of fault, refer to the „Rec-
tification of faults" section.
If the selector switch is in the "F" position when
the mains plug is plugged in, the machine will not
switch on.
Briefly move selector switch to "0" and then back
to "F" to switch on the machine.
EMERGENCY STOP switch
When the EMERGENCY STOP switch is pressed, the PC HP 30 is
switched off immediately.
Turn the EMERGENCY STOP switch in order to release it again.
The machine remains switched off after release. To switch it on
again, the selector switch must be briefly set to "0" and then
to "F".
4.2

DRIVE

When an overload occurs, the machine switches off automati-
cally (red indicator light lights up).
Move selector switch (Fig. 3, 2) to "0" and disconnect mains
plug. Set the pressure regulator (Fig. 3, 1) to "0".
Wait around 5 minutes, then plug the machine back in and
switch on. Set the required pressure.
The drive unit heats up during operation. This
is normal and not a sign of malfunction.
Dry running recognition
The PC HP 30 is equipped with dry running recognition.
If there is too little material / liquid in the container, the pump
speed will be reduced in order to minimise damage to the PC
HP 30. Refill the container immediately since even short pe-
riods of dry running can lead to damage to the rotor / stator.
If the container is not refilled within approx. 20 seconds, the
pump switches itself off automatically in order to prevent
more serious damage. After refilling, the pump must be re-
started again.
EN