Herunterladen Inhalt Inhalt Diese Seite drucken

Dismantling And Disposal - Comet KL 1680 GOLD PLUS Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 61
7.1 r
M
outInE
aIntEnancE
Follow the instructions in the "Switching off" section and abide by the recommendations in the table below.
INTERVAL FOR
MAINTENANCE
Each time used
Weekly
Monthly
CAUTION
• During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should
not drip from underneath it.
In this event, a Skilled Technician should test the appliance.
7.2 s
M
pEcIal
aIntEnancE
WARNING
• Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR
MAINTENANCE
Every 50 hours
Every 100 hours
CAUTION
• The data in the table are indications.

8 DISMANTLING AND DISPOSAL

Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current
regulations in the country where it is installed.
In particular, the symbol
of together with normal household waste.
For further information, contact your local authority's waste disposal service or your local retailer.
WARNING
• Before disposing of the high pressure cleaner, make sure it is no longer possible to operate it, by cutting the
power supply cable for example. Make sure all its parts are inoffensive, as they could prove to dangerous
to children playing.
• Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
• Cleaning the water inlet filter
Remove the water inlet fitting (a) and remove the filter (b) with pliers (see Fig. 6).
Cleaning the filter under running water or a burst of compressed air is usually
sufficient. For tougher dirt, use a product for removing lime scale or replace it.
Contact an authorised service centre to make sure you get the right spare part.
Replace the filter and secure the coupling fully.
• Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the
nozzle hole. In case you do not obtain any appreciable result, apply to an
authorised service centre.
• Check the pump hydraulic circuit.
• Check the pump fixing.
• Replace the pump oil.
• Check the pump suction/delivery valves.
• Check the pump screws are tightened.
• Check the pump adjustment valve.
• Check the safety devices.
on the identification plate (7) indicates the product must not be disposed
ACTION
ACTION