The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the device to the mains, it starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, UP and DOWN.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.

- STAND ALONE-MODE

 Slave Setting
 Sound Control Setting

- DMX-MODE

Stand-alone Mode
In the Stand Alone mode, the device can be used without a controller.
Slave Setting
Press the MODE button until the display shows SLA. The devices programmed thusly now function as
Slaves to the Master device.
Sound Control Setting
Press the MODE button until the display shows SoU.
The desired sensitivity (00 - 99) can be selected via the UP or DOWN buttons.
DMX Mode
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the device will respond to the controller.
Addressing
Press the MODE button until the display shows Add. You can now set the desired address (001 - 512) via
the UP or DOWN buttons.
Controlling:
After having addressed the LED TSR-400 RGBAW 3W DMX, LED D-400 RGBAW 3W DMX, or LED Z-400
RGBAW 3W DMX, you may now start operating it via your lighting controller.
Note:
It's necessary to insert the XLR termination plug with 120
proper transmission on the DMX data link.