Resistance:
Range
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
Capacity
Range
40 nF
400 nF
4 µF
40 µF
100 µF
Overload protection 600V
Frequency
Range
10 Hz – 10MHz
Overload protection 600V
Sensitivity ≤1 MHz : 300 mV; Amplitude max. 30 V
Sensitivity >1 MHz : 600 mV; Amplitude max. 30 V
Diode test
Test voltage
Resolution
Overload protection: 600 V
Acoustic continuity tester
56
VC265
±(1,6% + 3)
±(1,3% + 3)
±(1,6% + 3)
±(2,0% + 3)
Overload protection 600V;
Measuring voltage:
approx. 0.45 V
VC265
±(3,9% + 10)
±(3,9% + 5)
±(5,2% + 5)
VC265
±(0,1% + 8)
approx. 1.48 V
0.001 V
<10 Ω continuous sound, overload protection 600 V
Accuracy
VC280
±(1,6% + 3)
±(1,3% + 3)
±(1,6% + 3)
±(2,0% + 3)
Accuracy
VC280
±(3,9% + 10)
±(3,9% + 5)
±(5,2% + 5)
Accuracy
VC280
±(0,1% + 8)
Resolution:
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution:
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Resolution:
0.001 Hz – 0.01 MHz

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vc280

Inhaltsverzeichnis