Herunterladen Inhalt Inhalt Diese Seite drucken

E) Acoustic Continuity Test - VOLTCRAFT VC-12A Bedienungsanleitung

Analog-multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

e) Acoustic continuity check
Make sure that all the parts of the circuit, switches and
components and other objects to be measured are dis-
connected from the voltage and discharged.
The continuity test enables the quick check of a power line, for example.
If the continuity resistance is approx. <20 Ohm, a beep is emitted. The
pointer value does not correspond to the actual measured value!
Proceed as follows to make the measurement:
- With the rotary switch, select the measuring
range
.
- Connect the black measuring line to the
COM socket (5) and the red measuring line
to the „+" socket (6).
- Now perform the zero adjustment.
- Check it is functioning, by connecting both
measuring tips with each another.
- Now connect the two measuring probes to
the object to be measured (component,
switch etc.).
- If the resistance value is approx. <20 Ohm
an acoustic signal is emitted.
- After the measurement is completed, select
rotary switchposition „OFF" to „switch off" the
multimeter.
43

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis