Herunterladen Inhalt Inhalt Diese Seite drucken

EKOM DK50 2V/50/M Benutzerhandbuch Seite 70

Vorschau ausblenden Andere Handbücher für DK50 2V/50/M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 78
DK50 2x2V/110/M
Switch off the compressor every time before emptying the vessel!
Before the following checks it is required:
 For compressor variant with cabinet – unlock the door lock and open the cabinet door.
23.6. Check of safety valve
 Turn the screw (2) on the safety valve (1) several
times to the left until the safety valve releases the
air.
 Let the safety valve vent for a few seconds.
 Turn the screw (2) fully to the right, the valve must
be closed now.
Damage to the safety valve could cause pressure to rise to hazardous levels.
Never use the safety valve to release the air pressure in the air tank. This could
damage the safety valve. The valve is set to the maximum permitted pressure
by the manufacturer.
Never adjust a safety valve.
NP-DK50 2V 50, 2x2V 110-AD-2_05-2022
Fig. 24: Check of safety valve
70
PRODUCT MAINTENANCE
05/2022

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis