Fault
The display shows
"Warning !
Internal vessel overpres-
"
sure.
The display shows
"Warning !
"
Inter. vessel filled.
The display shows
"Warning !
Pressure inside the A/C
system
"
Recovery started!
The display shows
"Warning !
Pressure inside the
"
A/C system
The display shows
"Not enough vacuum.
"
Carry on?
The display shows
"A/C system leakage!
"
Continue?
The display shows
"Drained oil glass empty-
ing."
(ASC 2000, ASC 2000 RPA
and ASC 3000 only)
The display shows
"Warning !
Not enough vacuum
"
for injection!
The display shows
"Not enough refrigerant.
"
Add.
98
Cause
This message is normal dur-
ing the recycling process.
The internal refrigerant con-
tainer is too full to hold the
quantity to be extracted.
This message is normal at
the start of the vacuum pro-
cess. There is still pressure
present in the air conditioning
system.
Message during the vacuum
process. There is pressure in
the air conditioning system.
This message appears dur-
ing the vacuum process
when the pressure in the air
conditioning system after
8 minutes is still more than
50 mbar.
Message at the end of the
vacuum process. The air
conditioning system shows
a vacuum loss of more
than 120 mbar during the
checking time.
This message appears dur-
ing the extraction or recycling
process if there is more than
150 ml of used oil in the con-
tainer.
This message appears dur-
ing the filling phase
if the vacuum in the air condi-
tioning system is insufficient
to end the process.
This message appears dur-
ing the process input if there
is not enough refrigerant in
the internal container to com-
plete the process.
AirConServiceCenter
Remedy
To continue, press ENTER
for three seconds.
If the message appears more
than once, inform a technician.
Drain the internal refrigerant
container in the proper man-
ner.
No action is required.
The process continues auto-
matically.
No action is required.
The process continues auto-
matically.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Dispose of the content of
the used oil container in an
environmentally responsible
manner.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter
for leaks.
Fill the refrigerant container.