AirConServiceCenter
30. Disconnect the service hoses (11) and (12) and press ENTER
to confirm.
The service hoses are then emptied. The unit is then ready for
further use.
31. Put the valve caps of the vehicle air conditioning system back on
the connections.
8

Service tasks

8.1
Calibrating the scales
(only ASC2000, ASC2000RPA, ASC3000)
A
NOTICE!
In order for the oil quantities and the UV additive to be measured correctly,
the zero point of the scales must be checked regularly and reset if neces-
sary.
Resetting is necessary:
 If the quantity in a container deviates by more than 10 ml from the
target value
 If the AirConServiceCenter has been shaken, for example during
transport on bumpy roads
 Every four to six weeks
1. In standby mode, use the cursor keys
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor keys
A request to remove the container from the scale appears:
EN
Short selection
Free selection
Other selections
ENTER-OK
or
to select "Reset Scales":
Int.vessel filling
Flushing
Reset Scales.
Service.
Scale empty?
ENTER-OK STOP-EXIT
Service tasks
or
to select
87