Service tasks
10. Replace the O-rings (E).
11. Insert the new dryer and tighten the screw to max. 15°Nm.
8.3
Changing the filter for refrigerant analysis
(ASC2000RPA only)
I
NOTE
The refrigerant analysis filter (21), WAECO item number 4440600076,
needs to be changed once red spots begin appearing on the filter's
white surface.
1. Pull refrigerant analysis filter (21) from the bracket.
2. Disconnect both hoses from the filter.
3. Attach both hoses to a new refrigerant analysis filter. Observe flow
direction (arrow) when doing so.
4. Insert refrigerant analysis filter into bracket.
90