Example:
"Vor Klimaanlagen" shows the amount of extracted refrigerant. Here a
total of 18,650 g of refrigerant was extracted by the station in 2013.
Use the cursor key
for that year:
Press the cursor key
Here a total of 2,400 g of refrigerant was extracted in January 2013.
In the monthly overview, the filled and extracted amount is always dis-
played alternately.
Press "Enter" to print out the overview at any time. Press "STOP" to exit
the overview.
7.5
Air conditioning system test without refrigerant
service
I
NOTE
The air conditioning can only be tested on vehicles with a low pressure
port and a high pressure port, or with a low pressure port only.
If you only test the function of a vehicle air conditioning system without
drawing off and recycling the refrigerant, the vehicle air conditioning sys-
tem would be missing the refrigerant remaining in the service hoses
of the air conditioning unit after the test. The "A/C system test" menu
item has been added to compensate for this loss.
I
NOTE
The existing standard function processes "Short selection" and
"Free selection" already have a compensation function for service
hoses, which means the final air conditioning function test can be car-
ried out in the usual manner (the service hoses are drained by the unit).
EN
R134a from system
Total
g.
PRINT STOP-EXIT
to move to the next total amount of filling refrigerant
R134a to system
Total
g.
PRINT STOP-EXIT
to view the display for the monthly overview:
R134a from system
g.
PRINT STOP-EXIT
2013
18650
2013
9000
01/2013
2400
Operation