Operation

7
Operation
!
CAUTION!
When the air conditioning is serviced, the engine and the air condition-
ing must be switched off.
7.1

Short selection

I
NOTE
Fully automatic air conditioning service is started with the "Short selec-
tion" menu. You only have to enter the filling quantity as shown on the
label in the vehicle or the database.
The following actions are performed automatically in succession in the
"Short selection" menu:
 Sampling and analysis of the refrigerant (ASC2000RPA only)
 Extraction of the refrigerant
 Recycling of refrigerant (purity meets SAE J 2099)
 Pressure rise test
 Draining of used oil
 Nitrogen test (ASC2000RPA only)
 Leak test/overpressure check (ASC2000RPA only)
 Evacuation of the system
 Leak test/vacuum check
 Filling with fresh oil to the required quantity
 Filling of UV additive
 Filling of refrigerant
After every process is performed a service report is printed. Subsequent
actions are only initiated once the preceding action has been completed
successfully.
1. First fit the connections of the AirConServiceCenter to the vehicle
air conditioning system and open them.
2. In standby mode, use the cursor keys
"Short selection":
3. Press ENTER to confirm.
4. Use the keypad (7) and the cursor keys to enter the vehicle data.
5. Press ENTER to confirm.
74
Short selection
Free selection
Other selections
ENTER-OK
AirConServiceCenter
or
to select
EN