Verfügbare Sprachen

Verfügbare Sprachen

Encoder Interface Resolver / HTL Input
3.3.3

Connection of the encoder

• Encoder cable double-shielded and twisted in pairs
• Apply external shielding on both sides at the connector housing/inverter grounding
• Connect interior shieldings at one side to COM
• Do not connect exterior and interior shielding
• N+ is only required for posi function
Figure 3.3.3 Connection of the encoder
Motor encoder plug
Name
A+
COM
B+
COM
N+
COM
Uin
COM
Housing
3.3.4

Encoder cable

KEB encoder cables are corresponding to the following specification:
3.3.5

Encoder line length

The maximum line length of the encoder cable is 50 m. Please contact KEB if longer enco-
der cables are required.
3.3.6

Tested encoders

The following HTL-incremental encoder have been tested by KEB on it application:
ROD 436
However, this does not restrict the use of rotary encoder with same specifications of other
manufacturers.
��
��
��
PIN
5
10
8
10
3
10
12
10
-
Temperature range
Signal lines
Supply lines
Particularities
Color
Socket X3B
� �
PIN
Name
1
A+
8
COM
3
B+
8
COM
5
N+
8
COM
7
15/24 V
8
COM
PE inverter
trailing capable, oil resistant
constant up to 80 °C
Core color
green
yellow
blue
red
gray
pink
brown
white
shielding
3 x (2 x 0,14 mm²)
2 x 0,5 mm²
green RAL 6018
GB-13