Encoder Interface Resolver / HTL Input
3.2.3

Connection of the encoder

• Encoder cable double-shielded and twisted in pairs
• Apply external shielding on both sides at the connector housing
• Connect interior shieldings at one side at the interface to GND
• Do not connect exterior and interior shielding
Figure 3.2.3 Connection of the encoder
Motor encoder plug
��
PIN
10
11
Housing
3.2.4

Encoder cable

KEB encoder cables are corresponding to the following specification:
3.2.5

Encoder line length

The maximum line length of the encoder cable is 50 m. Please contact KEB if longer enco-
der cables are required.
��
��
1
5
7
2
Temperature range
Signal lines
Supply lines
Particularities
Color
Socket X3A
5
4
3
2
1
10
9
8
7
6
15
14
13
12
11
PIN Name
Core color
3
SIN_LO
red
8
SIN_HI
blue
5
REF_LO
yellow
10
REF_HI
green
4
COS_LO pink
9
COS_HI
gray
14
GND
interior shieldings
Housing
total shielding
3 x (2 x 0,14 mm²)
trailing capable, oil resistant
constant up to 80 °C
2 x 0,5 mm²
green RAL 6018
GB-9