Herunterladen Inhalt Inhalt Diese Seite drucken

Degree Of Protection; Anschlüsse - Bender RCMB104 Handbuch

Allstromsensitives differenzstrom-überwachungsmodul für ladesysteme für elektrofahrzeuge
Vorschau ausblenden Andere Handbücher für RCMB104:
Inhaltsverzeichnis

Werbung

Skalierung
RCMB104-1 ............................................ 0...100 % = DC 0...30 mA
RCMB104-2/ RCMB104-3M ................. 0...100 % = RMS 0...50 mA
Maximale Strombelastbarkeit ..................................................10 mA
* Der Überspannungsschutz muss kundenseitig sichergestellt wer-
den.
Steuereingang (TEST)
Ausführung .................................................LOW: aktivierter Zustand
................................................................HIGH: deaktivierter Zustand
Schaltschwellen ....................................................HIGH: 3,1... 5,5 V
.................................................................................. LOW: 0... 0,6 V
EMV (IEC 62752, UL 2231-2)
Einschränkungen ESD: Das Gerät muss in ein den genannten
Normen entsprechendes Gehäuse eingebaut werden.
Einschränkungen leitungsgebundene Störungen:
Maximale Anschlusslänge: .....................................................100 mm
ESD-Festigkeit nach Human Body Model JESD22-A114 ............... .....
....................................................................................... ±2 kV (Luft)
..................................................................................±2 kV (Kontakt)
Arbeitstemperatur .........................................................–30...80 °C
Lagertemperatur ............................................................–40...85 °C
Klimaklasse
Ortsfester Einsatz (IEC 60721-3-3) (keine Betauung, kein Wasser,
keine Eisbildung) ......................................................................3K24
Transport (IEC 60721-3-2) ..........................................................2K11
Langzeitlagerung (IEC 60721-3-1) .............................................1K21
Mechanische Beanspruchung
Ortsfester Einsatz (IEC 60721-3-3) ............................................3M11
Transport (IEC 60721-3-2) ...........................................................2M4
Langzeitlagerung (IEC 60721-3-1) ............................................1M12
Einsatzhöhe ........................................................................< 4000 m
Schutzart
RCMB104 .....................................................................................IP00
Messstromwandler (ohne Anschlussstecker) ..............................IP55
Anschlüsse
Messstromwandler
Anschlussart ................. Leiterplattensteckverbinder 0,65 x 0,65 mm
Rastermaß ...................................................... einreihig 6 x 2,54 mm
Kontaktoberfläche ................................................................verzinnt
Stiftlänge ................................................................................2,5 mm
Scaling
RCMB104-1 ............................................ 0...100 % = DC 0...30 mA
RCMB104-2/ RCMB104-3M ................. 0...100 % = RMS 0...50 mA
Maximum current-carrying ability ...........................................10 mA
* The overvoltage protection must be ensured by the customer.
Control input (TEST)
Type ................................................................. LOW: activated state
.......................................................................HIGH: deactivated state
Switching thresholds ............................................HIGH: 3.1... 5.5 V
.................................................................................. LOW: 0... 0.6 V
EMV (IEC 62752, UL 2231-2)
ESD restrictions: The device must be mounted in an enclosure that
complies with the mentioned standards.
Restrictions line-conducted interferences:
Maximum connection length: ...............................................100 mm
ESD immunity acc. to Human Body Model JESD22-A114 ............... ...
......................................................................................... ±2 kV (air)
...................................................................................±2 kV (contact)
Operating temperature ..................................................–30...80 °C
Storage temperature ......................................................–40...85 °C
Climatic class
Stationary use (IEC 60721-3-3) (except condensation, water and for-
mation of ice) .............................................................................3K24
Transport (IEC 60721-3-2) ..........................................................2K11
Long-term storage (IEC 60721-3-1) ...........................................1K21
Classification of mechanical conditions
Stationary use (IEC 60721-3-3) .................................................3M11
Transport (IEC 60721-3-2) ...........................................................2M4
Long-term storage (IEC 60721-3-1) ..........................................1M12
Range of use .......................................................................< 4000 m

Degree of protection

RCMB104 .....................................................................................IP00
Measuring current transformer (without connector plug) ..........IP55
Connections
Measuring current transformer
Connection type ....................PCB plug-in connector 0.65 x 0.65 mm
Modular dimensions .....................................single row 6 x 2.54 mm
Contact surface ........................................................................tinned
Pin length ...............................................................................2.5 mm
RCMB104_D00294_04_M_DEEN / 02.2023
RCMB104
17