• Finally, check whether the data set on the remote control and on the unit match. If necessary,
correct the values on the fixture as described in section 8.4.
• The luminaire is now ready to be controlled by remote control.
• The display of the remote control has an automatic switch-off. To reactivate the display,
briefly press the <ON / OFF> button.
• If channel 00 is selected, all luminaires on channels 1 to 99 can be controlled.

8.8.2 Switching the unit on / off / standby status by remote control

• Switch the unit on at the ON / OFF switch (if not already done). The <ON / OFF> function on
the remote control does not work when the main switch on the fixture is off.
• Press the ON / OFF switch of the remote control once briefly to activate the remote control.
• Make sure that the unit and the remote control are correctly connected and set to the same
channels (see previous section 8.8.1)
• By pressing the <ON / OFF> button on the remote control for a longer time
(approx. 2 - 3 seconds), you can switch off the fixture and put it into sleep mode.
• By pressing the <ON / OFF> button on the remote control twice, you can switch the light on
again with the remote control while in sleep mode.
• The remote control has an automatic switch-off function. To reactivate the display,
briefly press the <ON / OFF> button.

8.8.3 Setting the CCT mode

• Press the ON / OFF button on the remote control once briefly to activate the remote control.
• Make sure that the unit and the remote control are correctly connected and set to the same
channels (see previous section 8.8.1)
• Press the mode selection button once briefly until CCT appears in the display.
• Set the desired value for the colour temperature of the luminaire by pressing the plus <+> or
minus <-> buttons on the remote control. The first time you set a new value, the values on the
fixture are automatically synchronised with the settings on the remote control.
• The colour temperature of the luminaire changes and the selected values are shown
synchronously on the displays of the luminaire and the remote control.
• The colour temperature can be adjusted in steps of 100 from 3,200 to 5,600 Kelvin
• Set the black marker to the brightness by pressing the <up> or <down> button.
• Set the desired value for the brightness of the fixture by pressing the plus <+> or minus <->
buttons on the remote control. The first time you set a new value, the values on the fixture are
automatically synchronised with the settings on the remote control.
• The luminosity of the fixture changes and the selected luminosity values are shown
synchronously on the displays of the fixture and the remote control.
• The luminosity can be adjusted in 1 % steps from 10 to 99 %.