IMPORTANT
Any installation, electric or hydraulic
connection, programming, maintenance
operation, etc. must be carried out by
EN
QUALIFIED personnel AUTHORISED by
the manufacturer; operations carried out
by UNQUALIFIED personnel can jeopardise
the safety of the operator as well as other
personnel (user, etc.) or the system con-
nected to the dishwasher.
The manufacturer will not be held liable
for accidents to persons or objects resulting
from failure to comply with the above rules.
3.1
INSTALLATION (Fig. 6)
-
After having removed the packaging, make sure that
the machine is intact and that all the supplied parts
are present.
-
Position the machine in its final installation site and
level it by actuating the adjusting feet (20).
3.1.a DRAIN HOSE CONNECTION (Fig. 6)
-
Connect the drain hose (5) to a preset drain well.
Make sure that the drain hose runs flush along
the floor and has no bottlenecks.
3.1.b WATER CONNECTION (Fig. 6)
-
Connect the supplied filler hose (4) to the solenoid
valve and the other end of the filler hose (4) to a 3/4"
G threaded valve and apply the filter (8).
It is mandatory to connect the water supply
hose to a shut-off valve in order to separate
the supply system from the machine itself and
to check that there are no bottlenecks.
Wherever sand is found in the water supply circuit, a
filter must be applied between the water circuit and the
machine.
If it has none, it is recommended to install a descaler
upstream of the machine with calibration set to min 4
max 8 French degrees.
The manufacturer will not be held liable
for damage to the machines resulting from
failure to comply with the above rules.
26
IMPORTANT
ATTENTION
3.1.c ELECTRIC CONNECTION (Fig. 5)
DANGER
- Before performing the electrical con-
nection, make sure that the data on the
power line correspond to those indicated
on the rating plate (pos. 3 Fig. 5) and that
the main electric power switch upstream
of the machine is disconnected
(position O/OFF).
- An omnipolar power switch, appropriate-
ly sized with a minimum contact opening
of 3 mm must be installed between the
power line and the machine.
- Connect the power cable (9) to the main
switch upstream of the machine.
- Connect the equipotential earth electrode
to the terminal (7).
- The power cable CANNOT be replaced
by the user but ONLY by technical as-
sistance.
- There must be an efficient earthing sys-
tem, compliant with prevention standards
in force, for the safety of the operator
and the equipment.
- The power cable must not be pulled or
crushed during normal operation or rou-
tine maintenance.
- The equipotential terminal fixed to the
body must be connected to an equipo-
tential cable with a suitable cross-section
for the application.
- Respect the polarities of the wiring dia-
gram.
- For further information, see the attached
wiring diagram.
The manufacturer will not be held liable for
accidents to persons or objects resulting
from failure to comply with the above rules.